Page 75
VIS CAM 300/400 Installation Manual
Appendix B: J-Panel Functional and Connector Description
6.3.6 Indicators
There are two LED indicators mounted at the connector:
TABLE 22. LED indicators
6.3.7 Switches
There are two switches located at the connector:
TABLE 23. Connector switches
LED label LED color Indication
TRIG-1 green Indicates generation of trigger pulse to camera
off No trigger pulse
LC DATA LED not mounted
Power green 24V present at connector pin 10
red No 24V at connector pin 10
Switch label Switch type Function
S1 TRIG CAM-1 Push button Generates a trigger pulse to the camera
S5 TRIG POLARITY Slide Selects trigger polarity