TS-9720EN Series Progressive Scan Shutter Cameras
Page 35
Connectors and Cables
FIGURE 14. 12P-02S Interface Cable (optional)
Note: Make sure that the unused leads are not touching and that there is no possibility that
exposed wires could cause the leads to short.
5.3.3 Building Your Own Power Cable
Refer to the 12-pin connector pin-out in Section 5.1.1 on page 32. Connect the Ground lead to pin #1,
and the +12V DC lead to pin #2 of the 12-pin connector. Power must be DC-regulated, and of sufficient
current to properly power the camera.
5.3.4 Attaching the Power Cable to the Connector
The 12-pin connector is keyed and will only fit in one orientation. Follow these directions to properly
attach the power cable to the camera connector:
1. Rotate the connector while applying slight pressure until the keyways line up.
2. Press the connector into place until firmly seated.
3. Plug the power cord into the AC socket. This will power the camera up.
5.4 Attaching the Camera Lens
The TS-9720EN camera accepts 2/3" or larger format size C-mount lenses. To attach the C-mount lens
to the camera, carefully engage the threads and rotate the lens clockwise until it firmly seats on the
mounting ring. Do not force the lens if it does not seat properly. Please note that some lenses with
extremely long flangebacks may exceed the mounting depth of the camera.
12P-02S Interface Cable
Pin# Lead Color Function Pin# Lead Color Function
1 Gray GND 7 Black coax Reserved
2 Yellow +12V DC 8 White coax shield Reserved
3 Red coax shield GND 9 White coax Reserved
4 Red coax Video 10 Brown RXD
5 Orange coax shield GND 11 Blue Reserved
6 Orange coax VINIT IN 12 Black coax shield TXD
HD In (White Coax)
Video Out (Red Coax)
VD In (Black Coax)
Power (Yellow)
+12 V
Analog
Frame Grabber
GND (Gray)
}
Jack
Komentarze do niniejszej Instrukcji