Pulnix TM-250 Instrukcja Obsługi Strona 27

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 26
Page 21
Operation Mode
TM-250 Miniature CCD Camera
FIGURE 12. Trigger Position Reset/Restart Mode Timing
5.1.4 Trigger Width Reset/Restart Mode
The timing of the trigger pulse is not critical. It is, rather, the duration (width) that is important for
precise exposure time. The shutter pulse does not need to synchronize with Reset-Restart (EXT VD),
and can synchronize with moving objects.
A full picture field can be obtained on every other field, rather than on consecutive fields, as shown in
Figure 13, “Trigger Width Reset/Restart Shutter Mode Timing,” on page 22, because V shift has to be
stopped after the transfer pulse, and resume after the 11th line. Because V shift has been halted, part of
the field cannot be shifted out. To get a full picture field, the next shutter trigger must be prohibited,
which means a full picture is possible only on every other field. If a full picture field is required one
after another, the falling edge of the shutter pulse must fall between the 1st line and the 11th line to
ensure shift out of all the transferred charge from the previous transfer in FIELD accumulation mode.
This operation is similar to that of Trigger Position shutter, except that the timing is less critical.
TABLE 6. Trigger Position Reset/Restart Shutter Mode
F1
OFF
ASY
CYC
S3
0
S2
0
S1
0
S0
0
TRIGGER
Polarity
Up Down Up Up Up Down Positive
F2: not applicable.
EXT VD (R.R.)
TRIG
DSUB pulse
Transfer
Exposure
Video Out