Page 17
TM-250 External Signals
TM-250 Miniature CCD Camera
4.3 Width Mode Reset-Restart Operation
In Width Mode Reset-Restart operation, the leading edge and trailing edge of TRIG must both be
synchronized with external HD. In addition, the duration must be 1 line or longer in one-line step. If the
TRIG does not meet these conditions, the exposure time may vary from the position and the field.
Figure 7 below illustrates the proper operation with constant 2-line exposure period. Figure 8, on the
other hand, illustrates the illegal operation where the exposure time varies by the position of TRIG.
Shutter Trigger generates 1-line long-exposure at position A and 2-line-long exposure at position B
because the TRIG pulse is clocked in the same timing but the termination does not have the same
timing. The same happens by the difference of field (odd or even).
FIGURE 7. Proper Operation
FIGURE 8. Illegal Operation
HCLK
EXT HD
TRIG
Sample
Clocked in here
Exposure (A)
Exposure (B)
HCLK
EXT HD
TRIG (Case A)
TRIG (Case B)