Page 53
Serial Communication Kit
TM/TMC-4200CL Series Progressive Scan Cameras
Command Parameter End of Cmd Description
Byte 12 Bit 6 Password 0=Disable 1=Enable
Bit 7 Test Pattern 0=Disable 1=Enable
Byte 13, 14 (X1, Y1) Coordinate for Knee 1 (X1, Y1=H'00 - H'FF)
Byte 15, 16 (X2, Y2) Coordinate for Knee 2 (X2, Y2=H'00 - H'FF)
Byte 17, 18 Start Line of
Programmable
Scan Area
Start Line of Programmable Scan Area (H'0000 -
H'07FF)
Byte 19, 20 Total Lines of
Programmable
Scan Area
Total Lines of Programmable Scan Area (H'0001
- H'0800)
Byte 21, 22 Shutter Speed
of Programm-
able Shutter
Shutter Speed of Programmable Shutter (H'0000 -
H'081F)
Byte 23, 24 Vsub Voltage Vsub Voltage (H'0600 - H'0D00=7.8V - 17V)