3 Cognex MVS-8100C Hardware
Cognex MVS-8100C Hardware Manual 47
The schematic of the status output circuit is shown in Figure 21.
Figure 21. Status output schematic
Strobe Output
The strobe output is used to activate a photo strobe at the instant of image acquisition.
The device to be activated should have optically isolated inputs. The strobe output
signal is a pulse of 20 to 30 mA, with a duration of about two horizontal line scans. The
active sense (or polarity) of this output is high.
1 K
ILD2
+5V
1N916
1N916
24
75
4.7 K
PWR
STSOP
STSO
STSOR
GND