Page 15
Operation
TM-6760 Series Progressive Scan Shutter Cameras
the RS-232 interface will override the rear panel switch settings of the camera. The table below shows
details on various modes.
TABLE 6. Mode Selection Switch
Mode
Selection
Switch
Position Mode Information Up/Down Switch Functions
0 Switch disabled Switch disabled None
1 Set Gain Up / Down Change gain
2 Set Vtop (A/D) Up / Down Change A/D ref. top
3 Set Vbottom(A/D) Up / Down Change A/D ref. bottom
4 Gain Selection #1 Up: 9dB, Down: 12dB Lower gain selection
5 Gain Selection #2 Up: 18dB, Down: 22dB Higher gain selection
6 Linear LUT Up Back to linear table
7 Knee Selection Up / Down (Scroll) Scroll 8 different LUTs
8 Async Reset Mode Up: Normal, Down: Async Async and normal shutter
9 Factory default Recall Up / Down: Recall Factory setting
A Power up Setting Up: Recall, Down: Save Power up page setting
B User Page Storage #1 Up: Recall, Down: Save User page storage setting
C User Page Storage #2 Up: Recall, Down: Save User page storage setting
D Direct Shutter Control Up: Increment
Down: Decrement
Change “Direct shutter
speed in 1H increments
E Scan Format2 Up: PS200 Lines
Down: Two-row binning
Scan mode
F Scan Format1 Up: 60fps, Down: 30fps Scan mode